A coil does not like change. Try to start a current in it and it pushes back; try to stop the current and it pushes forward. That stubbornness is inductance, and it is the electrical cousin of inertia.

A rising current is opposed by the induced EMF, a falling one is supported

Self inductance

A changing current in a coil changes the magnetic flux through the coil itself, and by Faraday's law this induces an EMF that opposes the change (Lenz's law). The flux linked is proportional to the current:

NΦ = L I   |   ε = −L dI/dt   |   unit: henry (H) = V s/A

For a long solenoid of N turns, length l and cross-section A, with a core of permeability μ₀:

L = μ₀ N² A / l

L depends only on geometry and the core material, not on the current. Double the turns and L becomes four times larger.

Solenoid example: N = 500, l = 0.2 m, A = 4 cm² = 4 × 10⁻⁴ m². L = 4π × 10⁻⁷ × 500² × 4 × 10⁻⁴ / 0.2 ≈ 6.3 × 10⁻⁴ H = 0.63 mH.
Induced EMF: a 0.5 H coil in which the current rises from 0 to 2 A in 0.1 s. |ε| = L ΔI/Δt = 0.5 × 2 / 0.1 = 10 V, opposing the rise.

Energy stored

U = ½ L I²

For that 0.5 H coil carrying 2 A, U = ½ × 0.5 × 4 = 1 J. This energy sits in the magnetic field inside the coil. It is why switching off a big inductor suddenly produces a spark: the energy has to go somewhere.

Mutual inductance

Place two coils close together. A changing current in coil 1 changes the flux through coil 2 and induces an EMF there.

ε₂ = −M dI₁/dt   |   M = N₂Φ₂ / I₁

M is also in henry, and M₁₂ = M₂₁, a fact that is not obvious but always true. For two long coaxial solenoids, M = μ₀ N₁N₂ A / l.

Example: M = 2 mH, and the current in the primary changes at 50 A/s. The secondary EMF is 2 × 10⁻³ × 50 = 0.1 V.

Coupling coefficient and series combinations

The mutual inductance can never exceed the geometric mean of the two self inductances:

M = k √(L₁L₂),   0 ≤ k ≤ 1

With L₁ = 4 mH, L₂ = 9 mH and k = 0.5, M = 0.5 × 6 = 3 mH. If the two coils are connected in series, the total depends on how they are wound: L = L₁ + L₂ ± 2M. A plus sign means the fields help each other; a minus sign means they cancel partly.

Where inductance shows up

Transformers use mutual inductance, chokes in tube-lights use self inductance, and wireless chargers are two coils kept close. In an LR circuit, the current builds with a time constant τ = L/R, which you can see in our earlier note on the LR circuit.